Home | Survey | Payment| Talks & Presentations | Job Opportunities
Journals   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
High Voltage Engineering
1003-6520
2016 Issue 5
Recent Progress and Development in Test Methods for High Intensity Electromagnetic Field Radiation Effect
WEI Guanghui;LU Xinfu;PAN Xiaodong;National Key Laboratory on Electromagnetic Environment Effects;Mechanical Engineering College;
..............page:1347-1355
Parameters Influencing the Electrostatic Discharge Performance of Aircraft Static Dischargers
DUAN Zemin;QIU Shanliang;SI Xiaoliang;LI Zhibao;ZHANG Song;XU Haibo;Aviation Key Laboratory of Science and Technology on High Intensity Electromagnetic Environment Protection;Anhui Provincial Aircraft lightning Protection Laboratory;
..............page:1356-1362
Measurement of Liquid Food Equivalent Impedance Under Impulse Voltage
WEI Xinlao;LI Yulong;DING Xia;NIE Hongyan;WANG Yonghong;CHEN Qingguo;Key Laboratory of Engineering Dielectrics and Its Application;Ministry of Education;Harbin University of Science and Technology;
..............page:1363-1372
Formaldehyde Degradation and Ozone Generating Mass Concentration Control in Bipolar High Voltage Pulse Dielectric Barrier Discharge
DONG Bingyan;NIE Yalin;SU Yawei;XIE Yinyin;HE Junwen;WANG Hui;College of Resources and Environmental Engineering;Jiangxi University of Science and Technology;
..............page:1373-1378
Influential Factors and Mechanism of NO Removal in Flue Gas by High Voltage Corona Discharge with Liquid Chemical Oxidation
CAI Weijian;YU Jie;LI Jiwu;School of Environmental Science and Engineering;Zhejiang Gongshang University;
..............page:1379-1385
Evolutionary Design of High Robust Analog Circuit Based on Fault-tolerance Test
WU Huicong;WANG Jinze;ZHOU Wanzhen;Institute of Information Science and Engineering;Hebei University of Science and Technology;
..............page:1386-1393
Effect of High Voltage Electrode Geometry on the Discharge Characteristics and the Ozone Generation of a DBD Device
SHANG Kefeng;CAO Xiaomeng;WANG Xiaojing;LI Jie;LU Na;WU Yan;Institute of Electrostatics & Special Power;Dalian University of Technology;
..............page:1394-1400
Formation of Hydrogen Peroxide and Degradation of Dye Wastewater by Pulsed Discharge Plasma Combined with Activated Carbon
WANG Huijuan;GUO He;YANG Wenming;SUN Chenjing;LI Yang;YI Chengwu;School of the Environment and Safety Engineering;Jiangsu University;Jiangsu Collaborative Innovation Center of Technology and Material of Water Treatment;School of Material Science and Engineering;Jiangsu University;
..............page:1401-1408
Equivalent Model and Shielding Properties of Braid-reinforced Electromagnetic Protection Materials
QU Zhaoming;WANG Qingguo;WANG Xiaoliang;BAI Liyun;WANG Yan;Institute of Electrostatic & Electromagnetic Protection;Mechanical Engineering College;
..............page:1409-1414
Degradation of Methyl Orange Wastewater by DBD Combined with Granular Activated Carbon-supported Bi-metallic Oxides
TANG Shoufeng;YUAN Deling;ZHANG Qi;LIU Yameng;LI Jie;School of Environmental and Chemical Engineering;Yanshan University;Institute of Electrostatics and Special Power;Dalian University of Technology;
..............page:1415-1421
Optimal Design on Power Synthesis of Ultra-wide Band Dual-expotential Pulser with Fast Edge
LI Yang;ZHAO Min;LIU Xiaoting;ZHOU Xing;WANG Qingguo;YANG Qingxi;Shijiazhuang Worker University;Laboratory of Electromagnetic Environment Effect;Mechanical Engineering College;Hebei North University;
..............page:1422-1428
Deep Dielectric Charging of Exposed Dielectric of Satellite Considering Temperature Gradient
WANG Song;TANG Xiaojin;SUN Yongwei;WU Zhancheng;YI Zhong;Research Institute of Electrostatic and Electromagnetic Protection;Mechanical Engineering College;Beijing Institute of Spacecraft Environment Engineering;
..............page:1429-1435
Influence of Different Coupling Approach on Metal Enclosure Internal Electromagnetic Irradiation Coupling
LI Xinfeng;WEI Guanghui;WANG Liandong;HAN Hui;PAN Xiaodong;State Key Laboratory of Complex Electromagnetic Environment Effects on Electrontcs and Information Sysem;Institute of Electrostatic and Electromagnetic Protection;Mechanical Engineering College;
..............page:1436-1441
Performance Degradation of Antistatic Thermal Control Coatings Under Proton and Electron Irradiation
ZHAO Chunqing;DING Yigang;LIU Yuming;SHEN Zicai;Beijing Institute of Spacecraft Environment Engineering;
..............page:1442-1448
Theory Study of Ion Thruster Plume to Spacecraft Surface Charging
FENG Na;LI Detian;YANG Shengsheng;CHEN Yifeng;ZHAO Chengxuan;TANG Daotan;Lanzhou Space Technology Physics Institute;
..............page:1449-1454
Evaluation Method of Fine Particle Electrostatic Collection Efficiency Based on Image Identification
CAO Yunxiao;WANG Zhiqiang;WANG Jinjun;LI Guofeng;School of Electrical Engineering;Dalian University of Technology;
..............page:1455-1462
In Vitro Enhancement of Transdermal Delivery of 5-fluorouracil by Electret Application
WANG Chunxiao;GUO Xin;XU Lili;LIANG Yuanyuan;HUANG Ping;CUI Lili;JIANG Jian;Department of Physics and Mathematics;College of Basic Medical Sciences;Second Military Medical University;Department of Inorganic Chemistry;School of Pharmacy;Second Military Medical University;
..............page:1463-1469
Breakdown Characteristics and Emission Spectrum of Natural Ester Insulating Oil Under Positive Nanosecond Pulse Voltage
LI Wenyao;JIANG Nan;LI Jie;SHANG Kefeng;LU Na;WU Yan;Department of Electrical Engineering;Dalian University of Technology;Institute of Electrostatics & Special Power;Dalian University of Technology;
..............page:1470-1475
Electromagnetic Field Standard Device-monoconical TEM Cell
YANG Chao;MENG Cui;LI Penghui;JANG Tingyong;SHEN Daming;Key Laboratory of Particle & Radiation Imaging;Ministry of Education;Tsinghua University;Northwest Institute of Nuclear Technology;
..............page:1476-1482
Optimization of the Structural and Electrical Parameters of the Packed-bed-DBD Plasma Reactor Driven by Bipolar Pulsed Power
HU Jian;JIANG Nan;WU Yaguang;SHANG Kefeng;LU Na;LI Jie;Key Laboratory of Industrial Ecology and Environmental Engineering;Ministry of Education;Dalian University of Technology;School of Environmental Science & Technology;Dalian University of Technology;Institute of Electrostatics & Special Power;Dalian University of Technology;State Grid Customer Service Center;
..............page:1483-1488
Solution of Soil Structure Inverse Problem by GA of Variable Precision
SIMA Wenxia;WU Peng;YUAN Tao;BAI Yang;CHEN Wei;GUO Runsheng;State Key Laboratory of Power Transmission Equipment and System Safety and New Technology;Chongqing University;China Southern Power Grid EHV Maintenance & Test Center;Shuozhou Power Supply Subsidiary;
..............page:1489-1496
Simulation Analysis and Experimental Research of 10 kV Multiple-chamber Arc-extinguishing Lightning Protection Device with Strong Airflow
WANG Jufeng;WU Dong;LIANG Xue;LI Guodong;WANG Xinyang;College of Electrical Engineering;Guangxi University;
..............page:1497-1502
Optimization of Corrosion Diagnosis of Grounding Grid Based on Continuous Genetic Algorithm
LIU Yugen;SHANG Longlong;LENG Di;MI Hongwei;MA Jinpei;State Key Laboratory of Power Transmission Equipment & System Security and New Technology;Chongqing University;Shenzhen Power Supply Bureau Co.;Ltd.;
..............page:1503-1510
Lightning Protection Scheme with Shunt Gap for 35 kV Tube Composite Tower
LAN Lei;CHEN Zihan;LIU Zongxi;WANG Yu;DAI Min;LI Zhijun;School of Electrical Engineering;Wuhan University;China Electric Power Research Institute;
..............page:1511-1518
Lightning Over-voltage Fault Identification of High-voltage Transmission Line Based on Correlation Dimension and Extreme Learning Machine
MIAO Xiren;LIN Ruicong;College of Electrical Engineering and Automation;Fuzhou University;
..............page:1519-1526
Improvement in Lightning Protection Scheme of Subway Catenary with Viaduct Bridge
ZHANG Xueqin;CHEN Kui;LI Ruifang;HAN Hu;SHI Chaoqun;LI Kunpeng;School of Electrical Engineering;Southwest Jiaotong University;Guangzhou Metro Design & Research Institute Co.;Ltd.;
..............page:1527-1534
Lightning Protection Level for 500 kV High Altitude Transmission Lines in the Tibet Power Grid and Sichuan Power Grid Interconnection Project
CHEN Xiujuan;XIA Chao;YIN Yu;WANG Cheng;ZHANG Yadi;LIANG Ming;China Electric Power Research Institute;Southwest Branch;State Grid Corporation of China;Southwest Electric Power Design Institute Co.;Ltd.;China Power Engineering Consulting Group Co.;Ltd.;
..............page:1535-1540
Optimization Control of Niu-Cong HVDC Grounding Electrode Current Limitaion Function
ZHANG Yong;XIE Huifan;MEI Yong;XU Guanghu;ZHANG Jianxin;Power Dispatch and Control Center;China Southern Power Grid Co.;Ltd.;
..............page:1541-1547
Influence Factor of Impulse Characteristics of Box and Ray Grounding Device
YANG Shuai;LI Chaoying;TAN Bo;ZOU Jianming;LIU Huagang;ZHOU Wenjun;School of Electrical Engineering;Wuhan University;Xiamen Electric Power Supply Company;China Electric Power Research Institute;Center China Grid Company Limited;
..............page:1548-1555
Simulation on the Characteristics and Its Influence Factors of Lightning Intruding Wave in Substation
XIE Shijun;ZENG Rong;LI Jianming;ZHUANG Chijie;ZHANG Yu;CHEN Shaoqing;Electric Power Research Institute;State Grid Sichuan Power Company;State Key Laboratory of Control and Simulation of Power System and Generation Equipment;Department of Electrical Engineering;Tsinghua University;
..............page:1556-1564
Influence of Contact Bound on Interruption Characteristics of SF6 Circuit Breaker Under Multiple Lightning
WANG Qian;ZHU Kai;GUO Ze;LI Xingwen;School of Sciences;Xi’an University of Technology;State Key Laboratory of Electrical Insulation and Power Equipment;Xi’an Jiaotong University;
..............page:1565-1570
Microstructure and Performance Research of Carbon Nanotubes Filled Conductive Anticorrosion Coatings
WANG Limin;MENG Gang;MENG Xiaoming;CHEN Simin;WU Hao;Wuhan NARI Co.;Ltd.;State Grid Electric Power Research Institute;
..............page:1571-1577
Ablation Damage and Temperature Rise of Metal Oil Tanks Struck by Direct Lightning
LIU Yakun;XIA Hailiang;HE Yuwei;LIU Quanzhen;LIU Baoquan;FU Zhengcai;Key Laboratory of Control of Power Transmission and Conversion;Ministry of Education;Department of Electrical Engineering of Shanghai Jiao Tong University;State Key Laboratory of Chemicals Safety;Safety Engineering Institute;China Petroleum & Chemical Corporation;
..............page:1578-1585
Characteristics Analysis of Spatio-temporal Cluster of Lightning Based on Spatio-temporal Clustering
WU Weiwei;JIANG Congshi;TANG Zhenpeng;DOU Peng;HUANG Songbo;Jiangmen Meteorological Office;International School of Software;Wuhan University;Engineering Technology Research National Center of Geospatial Information and Digital Technology in National Administration of Surveying;Mapping and Geoinformation;Jiangmen Power Supply Bureau;Guangdong Power Grid Co.;Ltd.;Guangdong Power Grid Co.;Ltd.;Foshan Power Supply Bureau;Guangdong Power Grid Co.;Ltd.;
..............page:1586-1593
Lightning Transient Model of Isolation Transformer for High-speed Railway Track Circuit System
XIANG Nianwen;CHEN Weijiang;LI Chengrong;GU Shanqiang;YANG Jin;SUN Zheng;Beijing Key Labratory of High Voltage & EMC;North China Electric Power University;State Grid Electric Power Research Institute;State Grid Corporation of China;Beijing National Railway Research & Design Institute of Signal & Communication Co.;Ltd.;
..............page:1594-1599
Calculation and Analysis of Surface Magnetic Induction Intensity of Substation Grounding Grid Based on Robust Least Squares
WANG Shaojing;WANG Fenghua;SU Lei;SI Wenrong;LIU Yadong;Key Laboratory of Control of Power Transmission and Conversion;Ministry of Education;Shanghai Jiao Tong University;Electric Power Research Institute;State Grid Shanghai Electric Power Company;
..............page:1600-1607
Influence Factor and Simulation of the Loss of the Converter Transformer On-site Testing
ZHOU Yuanxiang;LIU Xinqu;WANG Mingyuan;HUANG Jianwen;ZENG Xiangjun;MI Chuanlong;State Key Laboratory of Control and Simulation of Power Systems and Generation Equipments;Department of Electrical Engineering;Tsinghua University;Electric Power Research Institute;China Southern Power Grid Company;Xi’an XD Transformer Co.;Ltd.;
..............page:1608-1616
Application of Bagging-CART Algorithm Optimized by Genetic Algorithm in Transformer Fault Diagnosis
HUANG Xinbo;LI Wenjunzi;SONG Tong;WANG Yanmei;School of Electronic Information;Xi’an Polytechnic University;Henan Special Equipment Safety Inspection Institute;
..............page:1617-1623
Influence of STATCOM System on the DC-icing Rectifier Transformers’ DC Magnetization and Suppression Method
LU Jiazheng;ZHU Siguo;LI Bo;ZHANG Hongxian;TAN Yanjun;ZHU Yuan;Power Transmission and Distribution Equipment Antiicing and Reducing-disaster Technology Laboratory;Disaster Prevention and Reduction Center;State Grid Hunan Electric Company;
..............page:1624-1629
Model-recognition-based Non-fault Detection Scheme for Three-phase Reclosure on Reactored Transmission Lines
SHAO Wenquan;ZHANG Wangni;XIA Jingde;LIU Yili;Department of Electronic and Information;Xi’an Polytechnic University;
..............page:1630-1635
Fault-line Selection Method for Double-circuit HVDC Line on the Same Tower Based on Single-circuit Information
LI Haifeng;MA Yanjun;WANG Gang;LIANG Yuansheng;School of Electric Power;South China University of Technology;
..............page:1636-1643
Influence of CaSO4 Mass Fraction in Contamination on the Leakage Current Characteristics of Porcelain Insulator String
HUANG Daochun;XIONG Ziteng;RUAN Jiangjun;LI Xiaobin;ZHANG Hu;TANG Yingkai;School of Electrical Engineering;Wuhan University;
..............page:1644-1650
On-line Monitoring Technique for Partial Discharge of High Voltage Explosion-proof Motor
ZHENG Xiang;LU Lihong;FU Wan’an;School of Electronics and Information Engineering;Dalian Jiaotong University;Center for Post-doctoral Studies of Control Science and Engineering;Dalian University of Technology;
..............page:1651-1658
Corona Audible Noise Experiment of UHV AC Double-circuit Line with Optimization of Insulator String Length
XIE Huichun;CUI Xiang;LU Yao;HE Wei;State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources;North China Electric Power University;State Key Laboratory of Power Grid Environmental Protection;China Electric Power Research Institute;
..............page:1659-1666
Measurement Research on Electron Attachment Cross Sections for Electronegative Gas with Ion Mobility Technique
ZHAO Feng;LI Shengli;LI Dong;HUO Mingxia;LI Jincheng;Jiyuan Power Supply Company;State Grid Henan Electric Power Company;Institute of Environmental Science & Engineering;Huazhong University of Science & Technology;China Electric Power Research Institute;
..............page:1667-1674
Protective Gap Operating Type of Live Working for EHV and UHV Transmission Lines Considering Elevation Factors
CAI Huanqing;SHAO Guiwei;FU Jing;HU Ji;CHEN Yi;WEN Zhike;China Electric Power Research Institute;
..............page:1675-1680